1. Adjustment of amplitude. The adjustment of the amplitude of the ultrasonic system of the ultrasonic vibrating screen plays a very important role. The adjustment of the amplitude should also be adjusted according to the characteristics of the material. The size of the vibration frequency is directly related to the size of the screening output. The adjusted vibration frequency is appropriate, which can not only meet the requirements of users, but also reduce the damage of screen, reduce the labor intensity of maintenance personnel and the capital investment of parts

 

2. Power adjustment. Users should note that the power of the ultrasonic vibrating screen is not the greater the adjustment, the better, the greater the amplitude, the better, but needs to be reasonably adjusted according to the screening effect of materials on the screen surface. When the screening effect is better when a small amount of materials are tested, the amplitude and power can be appropriately increased, and then a large amount of materials can be screened. This can avoid large energy consumption caused by excessive power of the equipment, and it is easy to reduce the service life of the screen. If the power is too low, the material handling capacity can not meet the user's requirements, and it is also easy to produce the phenomenon of screen surface material accumulation.